CHBXG - 650/35, THORNEL PAN BASED STANDARD (SUPAT)

  • MSDS: CHBXG
  • Manufacturer: AMOCO PERFORMANCE PRODUCTS INC
  • Product Name: 650/35, THORNEL PAN BASED STANDARD (SUPAT)
  • National Stock Number: 9390-00N085593
Product Identification

Product ID:650/35, THORNEL PAN BASED STANDARD (SUPAT)
MSDS Date:06/28/1994
FSC:9390
NIIN:00N085593
MSDS Number: CHBXG

Responsible Party
AMOCO PERFORMANCE PRODUCTS INC
200 EAST RANDOLPH DR
CHICAGO, IL 60601
US

Emergency Phone: 800-447-8735;800-424-9300(CHEMTREC)

Info Phone: 312-856-3340

Preparer: DONALD M BAKER

Cage: 15958

Contractor
AMOCO OIL CO
CHICAGO, IL 60601-6401 US

Telephone: 800 447-8735

Cage: 15958

Ingredients

CARBON; (CARBON FIBER, POLYACRYLONITRILE BASED)

CAS: 7440-44-0

RTECS: FF5250100

Fraction By Weight: 100%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 2 MG/M3 TDUST


TO GREAT LENGTH (>100 MICRONS). FIBERS W/DIAMETERS

RTECS: 9999999ZZ


ADVERSE HLTH EFTS WERE SEEN IN RATS FROM A 16-WEEK

RTECS: 9999999ZZ


FIBERS. NO COMPONENT OF PROD PRESENT @ LEVELS >0.1%

RTECS: 9999999ZZ


PROGRAM, THE U.S. OCCUP SFTY & HLTH ACT, OR THE IARC

RTECS: 9999999ZZ


COULD BE CONSIDERED HAZ IF IT MEETS

RTECS: 9999999ZZ


TO U.S. EPA DEFINITIONS (40 CFR SUBPART C). THIS

RTECS: 9999999ZZ


COMES INTO CONT W/LISTED HAZ WASTE. IF IT IS HAZ

RTECS: 9999999ZZ


MAN-MADE FIBERS. NIOSH REC AN EXPOS LIMIT OF 3.0

RTECS: 9999999ZZ


LENGTH >10 MICRON. AMOCO RECOMMENDS AN EXPOS

RTECS: 9999999ZZ


WORKWEEK FOR CARBON FIBERS. AMOCO HAS TAKEN

RTECS: 9999999ZZ


COUNT. CONCS OF AIRBORNE FIBERS MEASURED IN OUR MFG

RTECS: 9999999ZZ


FIBERS/CC IN WINDING OPERATIONS & 0.35 FIBERS/CC IN

RTECS: 9999999ZZ


OR TALCUM PROVIDE ADDNL PROT TO THE SKIN.

RTECS: 9999999ZZ


AS CHOPPING INCREASE POTENTIAL FOR SKIN IRRITATION.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYE & SKIN CONT: NO SIGNIFICANT
HEALTH HAZARDS IDENTIFIED. PARTICLES OR FIBERS MAY CAUSE SLIGHT
DISCOMFORT SIMILAR TO GETTING DUST IN EYE & RUBBING SAND AGAINST
THE SKIN. INHAL: NO SIGNIFICAT I RRITATION EXPECTED OTHER THAN POSS
MECHIRRITATION. INGEST: NO SIGNIFICANT HEALTH HAZARDS IDENTIFIED.
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: TOX INFO: SPECIFIC TOX TESTS HAVE NOT
BEEN CONDUCTED ON PROD. HAZ EVAL IS BASED ON INFO FROM SIMILAR
PRODS, INGREDS, TECHNICAL LITERATURE, AND/OR PROFESSIONAL
EXPERIENCE. DENSE DUST GENERATE D BY HNDLG AND/OR PROCESSING OF
THIS MATL MAY BE IRRITATING TO EYES, SKIN, NOSE & THROAT. THORNEL
CARBON FIBERS (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYE: FLUSH WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES. GET
MED ATTN IF IRRITATION PERSISTS. SKIN: WASH EXPOSED SKIN WITH SOAP
AND WATER. INHAL: IF ADVERSE EFFECTS OCCUR, REMOVE TO
UNCONTAMINATED ARE A. GET MEDICAL ATTENTION. INGEST: IF LARGE
AMOUNT IS SWALLOWED, GET MEDICAL ATTENTION.

Fire Fighting

Extinguishing Media:AGENTS APPROVED FOR CLASS A HAZARDS (E.G.,
HALOGENATED AGENTS, FOAM, STREAM) OR WATER FOG.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:FIBER, DUST & FIBROUS PARTICLES ARE
ELECTRICLLY CONDUCTIVE & CAN CAUSE SHORTING IN ELECTRICAL EQUIP.
EXPLOSIVE SHORTING OF HIGH VOLTAGE SYSTEMS IS POSSIBLE.

Accidental Release

Spill Release Procedures:CONTAIN AND REMOVE BY MECHANICAL MEANS. VACUUM
OR SWEEP OUT; AVOID PRODUCING DUST.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:MINIMIZE DUST GENERATION & ACCUM.
CARBON FIBERS ARE ELECTRONICALLY CONDUCTIVE & MAY CAUSE SHORT
CIRCUITS; RESULTS IN DMG TO/MALFUNCTIONING ELEC EQUIP.
Other Precautions:ALL FORMS OF ELEC EQUIP, ENCLOSURES & CIRCUITS
IN/NEAR AREAS WHERE FIBERS ARE USED/HNDLD SHOULD BE PROPERLY
PROTECTED AGAINST THE INFILTRATION OF OR CONTACT WITH AIRBORNE
PARTICLES OR FILAMENTS.

Exposure Controls

Respiratory Protection:IF VENT IS INADEQ, USE NIOSH APPRVD RESPIRATOR
THAT WILL PROTECT AGAINST DUST/MIST. CURRENTLY NO HLTH STDS EXIST
FOR EMPLOYEE EXPOS TO CARBON FIBERS. IN 1977, NIOSH PROPOSED THAT
THEIR REC STD FOR FIB ROUS GLASS BE APPLIED TO OTHER (ING 9)
Ventilation:NO SPECIAL CONTROLS NECESSARY. LOCAL EXHAUST VENTILATION
MAY BE NECESSARY FOR SOME OPERATIONS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER . LONG
SLEEVE GARMENTS W/TIGHT-FITTING CUFFS & USE OF BARRIER CREAMS (ING
14)
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MFR TRADE NAME/PART NO: MODULUS CARBON FIBERS. EFTS OF OVEREXP: ARE
NON-CRYSTALLINE(AMORPHOUS), MAN-MADE FIBERS. STUDIES CONDUCTED IN
AMOCO'S MFG FACILITY INDICATE THAT AIRBORNE CARBON FIBERS, IN GEN,
ARE NOT CONSIDERED RESPIRABLE. TYPICALCARBON FIBER MAY BE CHARACT
AS HAVING LG DIAMETER (5-7 MICRONS) IN ADDN (ING 2)

Chemical Properties

Melt/Freeze Pt:M.P/F.P Text:6512F,3600C
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:NEGLIGIBLE, <0.1%
Appearance and Odor:BLACK CARBON FIBER FABRIC OR CLOTH.

Stability

Stability Indicator/Materials to Avoid:YES
NONE IDENTIFIED.
Stability Condition to Avoid:AVOID GENERATING DUST.
Hazardous Decomposition Products:NONE IDENTIFIED.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE I/A/W APPLIC FEDERAL, STATE &
LOCAL REGULATIONS. DO NOT INCINERATE. BURIAL @ PERMITTED LANDFILL
IS REC. RCRA: THIS UNUSED MATL, WHEN DISCARDED/DISPOSED OF, IS NOT
SPECIFICALLY LISTED AS HAZ WASTE IN FEDERAL REGS; HOWEVER, IT (ING
6)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.